Opal-RT based Analysis and Implementation of DFIG with Standalone Wind Energy Conversion System

Authors

  • Saurabh Gupta

  • S C. Choube

  • Sushma Gupta

How to Cite

Gupta, S., C. Choube, S., & Gupta, S. (2018). Opal-RT based Analysis and Implementation of DFIG with Standalone Wind Energy Conversion System. International Journal of Engineering and Technology, 7(4.6), 339-346. https://doi.org/10.14419/ijet.v7i4.6.30921

Received date: June 20, 2020

Accepted date: June 20, 2020

DOI:

https://doi.org/10.14419/ijet.v7i4.6.30921

Keywords:

DFIG, Wind Speed, Vector Oriented Control, SWECS, Opal RT,

Abstract

In this paper, the detailed analysis and performance of a vector oriented control topology in Doubly-Fed Induction Generator (DFIG)-based wind power generation systems is discussed in order to produce a high quality of output voltage. The distortion of voltage and frequency control capabilities in both stator side and rotor-side converters (SSC&RSC) for unbalanced network condition are investigated. The control scheme is implemented in the synchronous rotating reference frame and provides specific current control for both the SSC and RSC. The primary objective of the control scheme is to maintain constant voltage and frequency under variable wind speed and operating conditions of load. Thus this technique is found to be capable of achieving minimum harmonic voltage distortion, thereby resulting in a nearly sinusoidal waveform to improve the power quality of the systems. The performance of the suggested topology is validated in real time environment using Opal-RT Lab simulator and adequate results were taken.

 

 

References

  1. [1] J. Kennedy, B. Fox and D.J. Morrow, “Distributed generation as a

    balancing resource for wind generation,†IET Renewable Power Gen

    eration, Vol. 1, No. 3, pp. 167-174, Sep. 2007

    [2] V. Valtchev, A. Van Den Bossche, J.Ghijselen, and J. Melkebeek,

    “Autonomous renewable energy conversion system,†J. of Renew.

    Energy, Vol. 19, No. 1/2, pp. 259-275, Jan.2000

    [3] G.M. Shafiullah n , Amanullah M.T. Oo, A.B.M. Shawkat Ali, Peter

    Wolfs, “Potential challenges of integrating large scale wind energy

    into the power grid–A review,†Int. Journal of Renewable and Sus

    tainable Energy Reviews, Vol. 20, pp.306–321, 2013

    [4] Jamal A. Baroudi, Venkata Dinavahi, Andrew M. Knight, “A review

    of power converter topologies for Wind generators,†Int. Journal of

    Renewable Energy, Vol.32, pp.2369–2385, 2007

    [5] B. Singh, K. Al-Hadded, and A. Chandra, “Active power filter with

    sliding mode control,†in Proc. Inst. Electr. Eng. Gener. Transmiss.

    Distrib., Vol. 144, No. 6, pp. 564-568, Nov. 1997

    [6] P. C. Krause, O. Wasynczuk, and S. D. Sudhoff, Analysis of Electric

    Machinery Piscataway, NJ: IEEE Press, 1995

    [7] L. Quazene and G. Mcpherson, “Analysis of the isolated induction

    generator,†IEEE Trans. Power Apparatus and Systems, Vol.PAS-102,

    No. 8, pp. 2793-2797, August 1983

    [8] E.G. Marra and J.A. Pomilio, “Induction generator- based system

    Providing regulated voltage with constant frequency,†IEEE Trans.

    Industrial Electronics, Vol. 47, No. 4, pp.908 - 914, Aug. 2000

    [9] S. Wekhande and V. Agrawal, “Simple control for a wind-driven

    Induction generator,†IEEE Industry Application Magazine, Vol. 7,

    No.2, pp. 4453, March/April 2001

    [10] Bin Lu, Xin Wu, Hernan Figueroa and Antonello Monti, “A Low cost Real Time Hardware in the loop Testing Approach of Power

    Electronics Controlsâ€, IEEE transactions on Industrial Electronics, Vol.54, No.2, pp 919-931, 2007.

    [11] V S Phani Kumar.Ch,R. Dileep Kumar, “Power Quality Improvement

    Of Grid Integrated Type- I Wind Turbine Generation System

    Operating as DSTATCOM by d-q Control Method†J. Electrical

    Systems, Vol-02,No.2, pp-278-290,2016.

    [12] A. K. Jain, V.T Rangnathan, “Wound Rotor Induction Generator

    with Sensorless Control and Integrated Active Filter for Feeding

    Nonlinear Loads in a Stand-Alone Grid,†IEEE Trans. of

    Ind.Electronics, Vol. 55, No. 1, pp.218-228, Jan 2008